Main Specifications for SSI-1000

Base System
    • Full digital 128 channel beam-former
    • Wideband pulse receiver
    • Super low noise TGC with 10 bit ADC
    • Progressive dynamic receive focusing
    • Progressive dynamic aperture opening
    • Progressive dynamic apodization
    • Broadband full digital complex demodulation for tissue and flow
    • Digital match filter for color Doppler processing
    • 40GB hard drive for in-system image storage
    • Compound imaging
    • Tissue Harmonic imaging
    • Revolutionary color and Doppler Algorithm to improve the flow sensitivity
    • Flexible hardware and firmware reconfiguration
    • Reliable Linux operation system
    • Natural resolution scan converter for 1024x768 high resolution display
    • Cine memory: typically 128 frames depending on the mode and sector size
    • Clip image Storage
    • Up to 10X smart Zoom
    • Multi-Port Probe Connection (up to 3)
    • LAN (DICOM) connectivity (TBD)
    • SVGA/DVI and Parallel port output for external image display and peripherals
    • USB2.0 flash mobile drive (>128MB) for off-line image storage and retrieving
    • Design for general practice and specialist clinic

Application

    • Abdominal
    • Vascular
    • Breast
    • Thyroid
    • Obstetrical
    • Gynecological
    • Muscular-skeletal
    • Cardiac
    • Urology

Image modes

    • Compound Imaging
    • Tissue Harmonic Imaging
    • 2-D
    • Color Doppler Imaging
    • Doppler Power Imaging (Color Power Angio)
    • PW Doppler
    • CW Doppler (optional)
    • M-mode
    • Zoom
    • Dual B and Real time dual color
    • Triplex

Transducers

    • LA10/38 High Density Linear Probe, 7-13Mhz
    • LA7.5/46 High Density Linear Probe, 5-10Mhz
    • CLA3.5/64 High Density Convex Probe, 70 and 90 degree
    • PA2.25 Phased Array Probe, 1.5-4Mhz
    • TV6.5 Endocavity Probe, 4-8Mhz
    • UCLA6.5 Endorectal Probe, 4-8Mhz
    • Others

User Interface control

    • B gain and flow gain
    • TGC
    • Depth control
    • Focal position/span
    • Dynamic range select
    • Tissue Harmonic image enable
    • Audio volume control
    • Freeze/cine
    • Image save
    • Zoom
    • Dual/ Real time Dual in color
    • L/R
    • Persistence
    • PRF
    • Wall filter select
    • Steering
    • Doppler Angle correction
    • Baseline movement
    • Time base scrolling speed
    • Annotation
    • Patient data input
    • Color ROI panning
    • Image sector width control

Peripheral

Note: Technical specifications subject to change and constantly upgrade without prior notice